sequential_loops.ll
2.66 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
; RUN: opt %loadPolly -polly-detect -analyze < %s | FileCheck %s
target datalayout = "e-p:64:64:64-i1:8:8-i8:8:8-i16:16:16-i32:32:32-i64:64:64-f32:32:32-f64:64:64-v64:64:64-v128:128:128-a0:0:64-s0:64:64-f80:128:128"
; Two sequential loops right after each other.
;
; void f(long A[], long N) {
; long i;
; for (i = 0; i < N; ++i)
; A[i] = i;
; for (i = 0; i < N; ++i)
; A[i] = i;
; }
define void @f1(i64* %A, i64 %N) nounwind {
; CHECK-LABEL: 'Polly - Detect static control parts (SCoPs)' for function 'f1'
entry:
fence seq_cst
br label %for.i.1
for.i.1:
%indvar = phi i64 [ 0, %entry ], [ %indvar.next, %for.i.1 ]
%scevgep = getelementptr i64, i64* %A, i64 %indvar
store i64 %indvar, i64* %scevgep
%indvar.next = add nsw i64 %indvar, 1
%exitcond = icmp eq i64 %indvar.next, %N
br i1 %exitcond, label %for.i.2, label %for.i.1
for.i.2:
%indvar.2 = phi i64 [ 0, %for.i.1 ], [ %indvar.next.2, %for.i.2 ]
%scevgep.2 = getelementptr i64, i64* %A, i64 %indvar.2
store i64 %indvar.2, i64* %scevgep.2
%indvar.next.2 = add nsw i64 %indvar.2, 1
%exitcond.2 = icmp eq i64 %indvar.next.2, %N
br i1 %exitcond.2, label %return, label %for.i.2
return:
fence seq_cst
ret void
}
; C-H-E-C-K: Valid Region for Scop: for.i.1 => return
; This one is currently not completely detected due to the PHI node in
; for.i.2 causing a 'PHI node in exit BB' error for the first loop. This should
; be fixed at some point. Such test cases do not really show up for us, as
; the -loop-simplify pass always inserts a preheader as in the test case below.
; Two sequential loops with a basic block in between.
;
; void f(long A[], long N) {
; long i;
;
; for (i = 0; i < N; ++i)
; A[i] = i;
; preheader:
; ;
;
; for (i = 0; i < N; ++i)
; A[i] = i;
; }
define void @f2(i64* %A, i64 %N) nounwind {
; CHECK-LABEL: 'Polly - Detect static control parts (SCoPs)' for function 'f2'
entry:
fence seq_cst
br label %for.i.1
for.i.1:
%indvar = phi i64 [ 0, %entry ], [ %indvar.next, %for.i.1 ]
%scevgep = getelementptr i64, i64* %A, i64 %indvar
store i64 %indvar, i64* %scevgep
%indvar.next = add nsw i64 %indvar, 1
%exitcond = icmp eq i64 %indvar.next, %N
br i1 %exitcond, label %preheader, label %for.i.1
preheader:
br label %for.i.2
for.i.2:
%indvar.2 = phi i64 [ 0, %preheader ], [ %indvar.next.2, %for.i.2 ]
%scevgep.2 = getelementptr i64, i64* %A, i64 %indvar.2
store i64 %indvar.2, i64* %scevgep.2
%indvar.next.2 = add nsw i64 %indvar.2, 1
%exitcond.2 = icmp eq i64 %indvar.next.2, %N
br i1 %exitcond.2, label %return, label %for.i.2
return:
fence seq_cst
ret void
}
; CHECK: Valid Region for Scop: for.i.1 => return